ISO 5349-2 PDF

The ISO Central Secretariat accepts no liability in this area. International Standard ISO was prepared by the European Committee for. Buy KS B ISO Mechanical vibration — Measurement and evaluation of human exposure to hand-transmitted vibration — Part 2: Practical guidance. ISO MECHANICAL VIBRATION – MEASUREMENT AND EVALUATION OF HUMAN EXPOSURE TO HAND-TRANSMITTED VIBRATION – PART 2.

Author: Miktilar Gataxe
Country: Portugal
Language: English (Spanish)
Genre: Finance
Published (Last): 27 December 2010
Pages: 89
PDF File Size: 16.78 Mb
ePub File Size: 1.82 Mb
ISBN: 832-5-15678-390-8
Downloads: 5304
Price: Free* [*Free Regsitration Required]
Uploader: Meztijar

It is important that FFT analyses use appropriate time windowing. Other accelerometer types, such as piezoresistive accelerometers, are not affected by DC-shift. For the use of mechanical filters to suppress vibration at very high frequencies, see annex C. The centre of gravity of the accelerometers shall not be lso than 20 mm away from the nearest hand.

In studying the tool, designers should consider the following:.

МКС EN ISO 5349-2:2010/A1:2016

Effects of Vibration on Users When excessive vibration is experienced by tool operators, they may experience symptoms of TVD total vibration disorder. The effect isoo the human body is dependent upon the magnitude of vibration, the frequency content, and the duration of exposure. In addition to vibration magnitude information, the evaluation of daily vibration exposure requires an evaluation of the duration of exposure to the operation per day.

The grinder is therefore operated for a total of s in each work cycle i. In other situations, changes have to be made to the power tools being used, e.

The principal requirement of the vibration type test standards is that measurements are made in the main gripping zone where the operator normally holds the power tool and applies the feed force. At a work rate of castings per day, the total daily exposure time is then min, i. The cut-off frequency of the mechanical filter is influenced by the mass of the accelerometer.

Back to Top 3. In the case of capacitively and inductively coupled interference signals, the effect of inevitable electromagnetic fields can be reduced by the following means: Vascular damage to the blood vessels, i. More sophisticated measurement systems are often based around some form of frequency analysis e.

  GORDON MARINO BASIC WRITINGS OF EXISTENTIALISM PDF

The minimum acceptable duration of measurements depends on the signal, instrumentation and operation characteristics. The measurement may include shocks such as those from dropping the power tool onto a work bench which are not part of the vibration exposure.

Learn more about our privacy policy. In this case the vibration measurement can be made over long periods during the normal use of the power tool, provided that any breaks in operation are part of the normal working procedure and that the operator does not lose contact with the power tool or hand-held workpiece, or significantly alter position of his hands on the power tool or hand- held workpiece.

You may find similar items within these categories by selecting from the choices below:. However, if the machine is designed to be held by a knob-handle on the housing, rather than by the housing itself, measurements shall be made on the knob-handle.

Review of Indian Standards Amendments are issued to standards as the need arises on the basis of comments. Where single-axis measurements are to be used, the single axis shall be the dominant axis. Ankita Art Printers Ph.: The directives help to establish a standard process by: Hand-Arm Vibration Syndrome is a general term used to broadly describe the physical damage to the hands, fingers, and related structures resulting from chronic exposure to excessive vibration.

ISO all partsHand-held portable power tools – Measurement of vibrations at the handle. NOTE 2 When investigating the history of exposure of individuals it is desirable, if possible, to measure the vibration of machines and inserted tools of different generations and different states of maintenance.

The vibration signal from the accelerometer can be processed uso a number of different ways to achieve a measure of the frequency-weighted acceleration. ISO recommends that the fundamental resonance frequency should be more than five times the maximum frequency of interest for hand-transmitted vibration, this corresponds to Hz.

An intermittent loss of signal connection can show up as DC-offsets, between which the signal appears normal. The number of significant places retained in the rounded off value should be the same as that of the specified value in this standard.

An Introduction to Hand/Arm Vibration – National Instruments

The mounting method chosen will be dependent on the particular measurement situation, each method 53449-2 its own advantages and disadvantages. Worldwide Standards We can source any standard from anywhere in the world. This does not preclude the free use, in course of implementing the standard, of necessary details, such as symbols and sizes, type or 53349-2 designations. In these cases – carry out a short-term measurement of vibration magnitude over a period of continuous operation.

  7300A EUROTHERM PDF

Back to Top 7.

An Introduction to Hand/Arm Vibration

Click to learn more. The goal for tool manufacturers should be to reduce vibrations through better design of tools.

Understanding Hand-Arm Vibration Hand-Arm Vibration is defined as the vibration workers experience when using tools such as chain saws, jackhammers, grinders, drills, etc. Due to technical changes in ISO Standard, this standard also revised in two parts.

The estimated vibration total value will therefore be 1 ,1 times the dominant axis vibration value. NOTE In practice, the sensitivity of accelerometers rarely drifts during measurements, however, they may suffer mechanical failure.

Everyday human beings interact with some sort of machinery, making contact with vibration inevitable.

InterRegs: EN ISO : | Mobile Construction Equipment

In general, the European and other vibration directives are designed to help employers reduce risk of employee injury and liability. ISOHuman response to vibration – Measuring instrumentation. The range of vibration total value 5349- was as follows: Where there is any doubt about the quality of the acceleration signal e.

This period may include variations in the vibration magnitude and may even include periods when there is no exposure. Whichever method is used for vibration measurement, the total exposure time per day has to be found. Some questions that can be used to help determine areas for HAVS concern: If the power tool is being operated for most of the period of use, one option is: For most practical measurements, the accelerometers are mounted either side of the 539-2 or on the underside of the tool handle adjacent to the middle of the hand.

Author: admin