LABTOOL 48 PDF

Find great deals for Advantech Lab Tool 48 Intelligent Universal EPROM Programmer 8 to 48 Pin. Shop with confidence on eBay!. All existing labtool can purchase the upgrade kit to upgrade the LabTool into. LabToolXP. LabToolXP advantage over the LabTool Thank you for purchasing the LABTOOLUXP intelligent universal Programmer . We designed this manual to help you quickly and easily set up and use your.

Author: Naktilar Mezilrajas
Country: Benin
Language: English (Spanish)
Genre: Literature
Published (Last): 20 September 2015
Pages: 417
PDF File Size: 6.55 Mb
ePub File Size: 2.88 Mb
ISBN: 113-6-78332-689-2
Downloads: 79081
Price: Free* [*Free Regsitration Required]
Uploader: Voodoobei

If you close this banner, or continue browsing, it means you consent for us to use cookies. In some order, here are the major parts on the board: This was state-of-the-art, 10 years ago. We may contact you regarding your error report for clarification. Im gonna guess the? This simply increments the serial numbers in the buffer each time a new device is inserted. Request higher bulk rates. We will check the case and contact you as soon as possible.

Calibration involves comparing the read values of a measuring instrument or data recorder with the corresponding values of a reference tool that meets the reference standards. After entering the Mass-production Mode, the production line operator inserts a device into the ZIF socket. This feature ensures that your device has been programmed properly, preventing failures due to programming errors and ensuring data retention.

After calibration is performed, you will receive an ISO certificate from Intertek, which is valid for 12 months. This feature ensures that your device has been programmed properly, preventing failures due to programming errors and ensuring data retention.

These seem to be driven by the output of the shift registers? A x2 — these are bit, high drive-capacity shift registers.

  AUSTIN OSMAN SPARE AUTOMATIC DRAWING PDF

Software update via web The LabToolUXP has additional safety features such as a built-in current limit and pin continuity check function. An error occurred the shopping list s could not be be loaded.

You will find two items appearing, one version without a calibration service item-nr.

The Vcc voltage can be 2. Usually the time for the calibration of your device can be handled within 5 working days.

Please tell us what you think about our web site, company, products, or services. This advanced pin design lets you program any DIL device of up to 48 pins without needing an adapter.

LABTOOL-48UXP – Programmer USB/Parallel Port – Advantech Equipment

Please visit our website to find instruments which can be calibrated. Serialization function If your memory devices need individual serial numbers labyool different increment sequence and initial value, the LabToolUXP has an Auto Increment function. If the detected deviation is too large in relation to factory specification, adjustment of your data logger or measuring instrument will be required. The measured values detected by the calibration Calibration in a controlled environment measuring laboratory.

Advantech Lab Tool 48 Intelligent Universal EPROM Programmer 8 to 48 Pin | eBay

Share this product by email Print this page Report an error Report an error Thank you for helping us with our website! Our expert team have over 25 years experience solving problems and providing expert advice. You need to register to use this feature.

Thank you for your message. Shall we take a look? This additional time for the calibration should be taken into consideration to your normal delivery time. This function protects your pocketbook by preventing expensive chip damage due to operator error. Our website uses cookies, from us and third parties, to personalise your experience and show you products and adverts that may be of interest to you.

  LOZI DICTIONARY PDF

Auto-sensing and self-programming To meet mass-production requirements the LabToolUXP has implemented new patented technology in both its hardware and software. If you wish to change your cookie settings, or learn more about cookies, click here. Please contact our partner Intertek directly for a re-calibration of your device: After the order has been placed for the calibrated version, the non-calibrated device will be sent out from our warehouse to the calibration institute of Intertek Calibration service in process at Intertek Creating the certificate for end user The device will be repacked and sent directly to the end user.

LabToolUXP Upgrade Kit

We have developed over different adapters to support these special-package devices. Each driver can source mA, and it has an overcurrent detection output, which is fed back into the controller circuitry and causes the device to give you an error message when you put your chips in backwards.

No formal training is necessary adding flexibility and saving time and money. Technological innovation and performance leadership Device insertion and contact checks—No mistakes! This saves time and money. In addition, the LabToolUXP’s auto-sensing feature ensures the device has been inserted correctly and then automatically programs the device. Presumably used to drive the 4 power supplies Vcc, Vpp1, Vpp2, Vpp3 mentioned in the 84 copy Power supply section — what we have here is an LMT used as a general voltage regulator?