ASTM F2413 05 PDF

1 | Page. ASTM. American Society For Testing and Materials. F Standard Specification for Performance Requirements for Foot. Protection. Abstract. Learn about ASTM footwear standards and how to properly read a label. The 11 after the dash signifies the footwear meets the ASTM F or F ASTM F EH Overshoes are made from yellow ozone resistant rubber that’s % waterproof.

Author: Kazragor Akinotaur
Country: Comoros
Language: English (Spanish)
Genre: Photos
Published (Last): 12 March 2011
Pages: 491
PDF File Size: 18.20 Mb
ePub File Size: 7.66 Mb
ISBN: 960-8-29939-562-3
Downloads: 39336
Price: Free* [*Free Regsitration Required]
Uploader: Akinogar

Add-On Devices An important point to remember is that neither the ANSI nor ASTM standards allows for the use of add-on type devices — strap-on foot, toe or metatarsal guards — as a substitute for protective footwear. This specification covers the minimum design, performance, testing, and classification requirements, and prescribes fit, function, and performance criteria for footwear designed to be worn to provide protection against a variety of workplace asttm that can potentially result in injury.

asrm

Conductive Cd footwear is intended to provide protection for the wearer against hazards that may result from static electricity buildup and to reduce the possibility of ignition of explosives or volatile chemicals. The marking satm be enclosed in a rectangular border and a four line format is suggested. The purpose of metatarsal footwear is to prevent or reduce the severity of injury to the metatarsal and toe areas.

It is intended to provide a secondary source of protection against accidental contact with live electrical circuits, electrically energized conductors, 2f413 or apparatus. This line identifies the D2413 standard. Learn how your comment data is processed. This line identifies the applicable gender [M Male or F Female ] for which the footwear is intended. Most manufacturers of add-on devices have submitted their products to independent laboratories for testing.

Line 4 is only used when more than three sections of the ASTM standard apply. It also identifies the existence of impact resistance Ithe impact resistance rating 75, 50 or 30 foot-poundscompression resistance C and the compression resistance rating 75, 50 or 30 which correlates to pounds, asstm, and pounds of compression respectively.

Post was not sent – check your email addresses! This plate f24133 an integral and permanent part of the footwear.

OSHA & ASTM Protective Footwear Requirements

Link to Active This link will always route to the current Active version of the standard. You are commenting using your Twitter account. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

  BALANCEO DE ECUACIONES QUIMICAS REDOX PDF

Historical Version s – view previous versions of standard. All footwear manufactured to the ASTM specification must be marked with the specific portion of the standard with which it complies.

ASTM F2413-05 EH Footwear Overshoes

Following these assessments, the requirements of additional sections—such as metatarsal protection, conductive protection, electric hazard resistance, static dissipative protection, and protection against punctures—can be met.

This data and its results can be obtained upon request. Accept all cookies or Manage cookie settings. The device must show no sign of corrosion after being exposed to a five percent salt solution for 24 hours.

The footwear must withstand a minimum force of pounds. Footwear conforming to this specification shall meet the performance requirements for the following: A work boot that meets the impact and compression requirements of the ANSI standard may not provide protection for metatarsal, electrical or penetration hazards. It also identifies the existence of impact resistance Ithe impact resistance rating 75 or 50 foot-poundscompression resistance C and the compression resistance rating 75 or 50 which correlates to pounds and pounds of compression respectively.

PR CS Lines 3 and 4 are used to identify footwear made to offer protection from other specific types of hazards referenced in the standard. These references can be found in The letters PT indicate the protective toe section of the standard. This abstract is a brief summary of the referenced standard.

Devices constructed of metal must pass the corrosion resistance testing and show no sign of corrosion after being exposed to a five percent salt solution for hours.

Standard specification for performance requirements for protective safety toecap footwear. All footwear manufactured to this ASTM specification must be marked with the specific portion of the standard with which it complies.

It allows employers to use PPE constructed in accordance with any of three national consensus standards the two most recent and the incorporated reference in the current standards. The metatarsal designation Mt and rating i.

Sorry, your blog cannot share posts by email. This specification covers the minimum design, performance, testing, and classification requirements, and prescribes fit, function, and performance criteria for footwear designed to protect against a variety of workplace hazards.

It also identifies the existence of impact resistance Ithe impact resistance rating 75, 50 or 30 foot-poundscompression resistance Cand the compression resistance rating 75, 50, or 30, which correlate to pounds, pounds, and pounds of compression respectively. Dielectric insulation DI footwear is designed to provide additional insulation if accidental contact is made with energized electrical conductors, apparatus or circuits.

  LA DIRIGENZA INFERMIERISTICA CALAMANDREI PDF

Aetm to the ANSI and ASTM standards, any protective toe caps or metatarsal guards must be designed, constructed and manufactured into the protective footwear during the manufacturing process and tested as an integral part of the footwear.

ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. The electrical resistance must range between zero andohms.

Line four is to be used when more than three sections of the standard applies to the footwear.

It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. This line identifies the gender [M Male or F Female ] of the user. Puncture resistant PR footwear is designed so that a puncture resistant plate is positioned between the insole and outsole.

It is intended to protect the foot area between the toe and lower leg. Static dissipative SD footwear f24133 designed to provide protection against hazards that may exist due to excessively low footwear resistance, as well as maintain a sufficiently high level of resistance to reduce the possibility of electric 055.

Safety and client access have no downtime. The r2413 of this standard is to summarize the requirements for certifying protective footwear by independent, third party laboratories.

ASTM F – 05 Standard Specification for Performance Requirements for Foot Protection

Any changes to the original components of safety toe footwear, such as replacing or adding foot beds or inserts, could cause failure to any or all parts of the ASTM standard invalidates the safety marking.

Static dissipative SD footwear is designed to provide protection against hazards associated with exceedingly low footwear resistance and to maintain a sufficiently high level of resistance to reduce the possibility of electric shock. I’m a client Email.