IEC 584-3 PDF

THERMOCOUPLE. GRADE. EXTENSION. GRADE. PLUG &. JACK. IEC IEC Intrinsically Safe. BS DIN JIS C NFC T. Kit with a galvanized plate (KSP) for compost probe. Possible fixing with anti-thief device KAV of KISTOCK dataloggers or magnetic fixing of protective housing. IEC. Première édition. First edition. Cou p les therm oé lect riq ues. Troisième partie: Câbles d?extension et de compensation -. Tolérances et sy.

Author: Todal Niran
Country: South Sudan
Language: English (Spanish)
Genre: Art
Published (Last): 10 July 2007
Pages: 444
PDF File Size: 17.89 Mb
ePub File Size: 15.74 Mb
ISBN: 476-6-13367-189-5
Downloads: 34610
Price: Free* [*Free Regsitration Required]
Uploader: Samujora

The electronics with the stored calibration data included is dimensioned such that the standardized measurement accuracy can be guaranteed.

Our pressure sensors are supplied in adequate housing, equipped with all necessary cabling, power supplies, etc. Thermocouple sets Thermocouple sets are fitted: Each analog thermocouple signal is converted to digital signal at a precision of 16 bits; in this range this means a real accuracy of at least 0.

The various elements of the set are then provided a number marking to recognize Individual thermocouples. Moreover there is also the possibility of connecting your own separate pressure sensor. Thermocouples are available as separate elements, on one side provided with a thermocouple connector and on the other side finished with a soldered point and insulation.

Due to the temperature compensation the accuracy stability can be guaranteed for at least a year, so a 1 x annual calibration can suffice. The embedded micorprocessor in TSA 2 communicates digital measurement data with the externally connected personal computer and also processes control commands of the PC for setup and operation of the measurement system.

After a one-time setup of the desired calibration points up to 10 points are allowedthey are automatically run through under the control of the TSA2 and ValidR.

  FOURTOUTICI JOURNAUX PDF

ANSI and IEC color Codes and limits of error for Thermocouples, Wire and Connectors

In combination with the TSA2, the metal block oven has the following properties: Measuring a minimal change in theoretical temperature of 0. Miscellaneous A pressure sensor is supplied with a calibration certificate traceable to international standards. Several individual thermocouples are assembled to thermocouple sets with or without a pressure tight feedthrough.

This pressure sensor is ideally suited for measuring the vessel pressure during steam sterilization processes: Individual Thermocouples are available as separate elements, on one side provided with a thermocouple connector and on the other side finished with a soldered point and insulation. For the metal block oven option, in combination with the thermocouple calibration facility, an accuracy of 0.

A unique feature is the ability to connect this input by means of a relay to the sterilizer control system, with which the exact phase transition of that control can be detected. But for type T thermocouples additional hardware could be integrated recalibration with resistors.

Electronic Sensor – Thermocouples of IEC

A change in temperature of 0. For a improved placement and thermal stabilization of the thermocouples during the calibration procedure, it is advisable to make use of so-called thermocouple heating tubes: A particular advantage of this metal block oven is its ability to execute programmable calibration procedures in combination with the ValidR validation software.

In order to independently monitor the temperature of the metal block oven MBO during calibration use can be made of a Catch-T model ITCS with pt sensor and separate digital readout:. The use of type K or type J thermocouples is recommended. For a improved placement and thermal stabilization of the thermocouples during the calibration procedure, it is iev to make use of so-called thermocouple heating tubes:.

  EDEN ROLT MILLIONTH COMPARATOR PDF

We make a distinction with regard to pressure sensors in accuracy and stability. Sets of thermocouple heating tubes with 6 holes for 6 thermocouples.

The scanner comes including: It is also possible to enter a desired point of time at which the calibration procedure is then started automatically. Type and the length are at your choise.

For example, two pressure sensors can have the same accuracy, but the stability, among other things as a result of temperature variations of iecc of the two pressure sensors, may be such that the accuracy can not be guaranteed over a longer period of time. Other configurations of thermocouple sets are available on request, for example: This pressure sensing system has a range of 0 to kPa and an accuracy of 0.

The lesser accuracy can than be idc by software. By means of this integrated functionality, the entire calibration procedure can be carried out independently and unattended. Programmable calibration procedures A particular advantage of this metal block oven is its ability to execute programmable calibration procedures in combination with the ValidR validation software.

The most well known use is in the IAVS-M2 systems see below for detailswhich provides the interface between the measuring sensors and the software in a portable computer, which registers and records the measurements in charts and tables. For these types linearisation hardware is standard available ICresulting in a situation with high accuracy.

Author: admin