Jis b pdf. DownloadJis b pdf. Free Pdf Download Computer Experience. Intermediate Location Minnesnowta Type 3 JDBC Driver BDP-BX1 S Find the most up-to-date version of JIS B at Engineering the Appendix 11 of JIS B (Construction of pressure vessel — General . JIS B. (Pressure vessels–General standard) or standards.

Author: Marg Tygor
Country: Algeria
Language: English (Spanish)
Genre: Life
Published (Last): 8 April 2008
Pages: 253
PDF File Size: 16.61 Mb
ePub File Size: 7.98 Mb
ISBN: 552-8-74548-413-1
Downloads: 80090
Price: Free* [*Free Regsitration Required]
Uploader: Goltigis

Scope The welding of the any parts of First Class pressure vessels that are subject to pressure shall be in accordance with the provisions jiw this section unless such parts are free of any stress other than compressive one.

Efficiency of Welded Joints 1. For test plates not less than 19 mm in thickness, longitudinal root bend tests may be substituted for root bend tests except in examining double-butt-welded test plates, for which a longitudinal face bend test may be used in place of a face bend test.

  ALPHACOOL HEATMASTER PDF

Root bend test which may be replaced by a face bend test in examining double-butt-welded test plates. The efficiency of any welded joint in the preceding paragraph shall be equal to the appropriate one of the values specified in the right column of the following table for different types of welded joints listed in the left column thereof: Holes in Weld zones 1.

For test plates less than 19 mm in thickness, longitudinal face bend and longitudinal root bend tests may be substituted for face bend and root bend tests, respectively.

However, this does not apply to those weld zones that have passed radiographic examination. The radiographic examination referred to in the exceptive clause of the preceding paragraph shall cover an area extending over at least 1.

Type of welded joint.

Welding of any parts which are liable to significant bending stress shall be avoided. If there is a significant difference of elongation between the base metal of the test plate and that of the weld assembly or between the weld assembly and weld metals, the mechanical test may be performed by the appropriate one of n procedures specified below:.

  LOCTITE 2760 PDF

Workmanship and Hydraulic Tests Section 1.

Welding shall be made in iis a way that the weld zones have necessary strength for safety. The allowable tensile stress of weld zones shall be the value that is obtained multiplying the figures calculated using the Article 3 or the Article 4 by the efficiency of the welded joint. No hole may be made in any weld zone including the adjacent areas within 6 mm from the edges of the welded metal.